Autor Mohammad Abu Sayem Karal

Focused Impedance Measurement (FIM) system uses six electrodes to localize a zone of interest. The present work represents a modified FIM technique using four electrodes placed at the corners of a square matrix. In this technique ... celý popis

62.38

Bežne: 63.63 €

Ušetríte 1.25 €


Skladom u dodávateľa
Odosielame za 15 - 20 dní
Pridať medzi želanie

Mohlo by sa vám tiež páčiť

Darčekový poukaz: Radosť zaručená
  1. Darujte poukaz v ľubovoľnej hodnote, a my sa postaráme o zvyšok.
  2. Poukaz sa vzťahuje na všetky produkty v našej ponuke.
  3. Elektronický poukaz si vytlačíte z e-mailu a môžete ho ihneď darovať.
  4. Platnosť poukazu je 12 mesiacov od dátumu vystavenia.

Objednať darčekový poukazViac informácií

Viac informácií o knihe Study a New Four-Electrode Focused Impedance Measurement (FIM) System

Nákupom získate 157 bodov

Anotácia knihy

Focused Impedance Measurement (FIM) system uses six electrodes to localize a zone of interest. The present work represents a modified FIM technique using four electrodes placed at the corners of a square matrix. In this technique firstly current is driven through an adjacent electrode pair while the potential is measured across the opposite pair from which an impedance value is obtained. Then a similar measurement is made at 90 degree to the above by changing the electrode pairs appropriately. The sum of these two impedance values has a dominant contribution from the central region within the square matrix, giving the desired focusing. Measurements made on a 2D phantom have verified the desired performance successfully in the present work. Results presented through sensitivity maps and sensitivity curves using insulating, conducting objects and an object of organic conductivity (potato) demonstrate the focusing effect clearly. Because of 3D sensitivity it could give physiological information on large organs like stomach, lungs, etc. using surface electrodes in the frontal and transverse plane.

Parametre knihy

Zaradenie knihy Knihy po anglicky Mathematics & science Physics Applied physics

62.38

Obľúbené z iného súdka



Osobný odber Bratislava a 2642 dalších

Copyright ©2008-24 najlacnejsie-knihy.sk Všetky práva vyhradenéSúkromieCookies


Môj účet: Prihlásiť sa
Všetky knihy sveta na jednom mieste. Navyše za skvelé ceny.

Nákupný košík ( prázdny )

Vyzdvihnutie v Zásielkovni
zadarmo nad 59,99 €.

Nachádzate sa: