Flat Plate Multi Storied Frames with and without RC Infilled Walls / Najlacnejšie knihy
Flat Plate Multi Storied Frames with and without RC Infilled Walls

Code: 14445812

Flat Plate Multi Storied Frames with and without RC Infilled Walls

by P. M. B. Raj Kiran Nanduri, Dean Kumar Boda

In high rise buildings Flat plate floor structures are uncertain in resisting lateral loads. Hence lateral load resisting systems like Braced walls, outriggers, structural walls like RC Infill Walls and shear walls are to be provi ... more

47.31

RRP: 52.40 €

You save 5.09 €


In stock at our supplier
Shipping in 9 - 11 days
Add to wishlist

You might also like

Give this book as a present today
  1. Order book and choose Gift Order.
  2. We will send you book gift voucher at once. You can give it out to anyone.
  3. Book will be send to donee, nothing more to care about.

Book gift voucher sampleRead more

More about Flat Plate Multi Storied Frames with and without RC Infilled Walls

You get 119 loyalty points

Book synopsis

In high rise buildings Flat plate floor structures are uncertain in resisting lateral loads. Hence lateral load resisting systems like Braced walls, outriggers, structural walls like RC Infill Walls and shear walls are to be provided. In the present work a comparative study has been conducted with respect to the height of the RC framed structure i.e. number of storeys of the RC framed structure such as 20 storey, 40 storey, 60 storey and 80 storey are analyzed using STAAD.PRO(V8i) software. For each of these structures three comparisons have been made; one comparison is Conventional Beam supported slab structure compared with Flat Plate RC Framed structure, Flat Plate Framed structure compared with Flat Plate Framed structure having external peripheral RC Infill Wall and Conventional Beam supported slab Framed structure compared with Flat Plate Framed structure having external peripheral RC Infill Wall.In these comparisons the Critical Column Axial Forces, Critical Column moments due to gravity and wind loads and Lateral Drift (in mm) in X, Z direction due to Wind loads are observed. Basic wind speed of 44 m/s is considered for these structures located at Hyderabad, INDIA.

Book details

47.31

Trending among others



Collection points Bratislava a 2642 dalších

Copyright ©2008-24 najlacnejsie-knihy.sk All rights reservedPrivacyCookies


Account: Log in
Všetky knihy sveta na jednom mieste. Navyše za skvelé ceny.

Shopping cart ( Empty )

For free shipping
shop for 59,99 € and more

You are here: